COMPARATIVE PERFORMANCE EVALUATION OF IMPORTED AND LOCALLY FABRICATED ELECTRICAL RESISTIVITY METERS FOR SUBSURFACE INVESTIGATIONS

Authors

Keywords:

Resistivity Meter, 2-D Imaging, Vertical Electrical Sounding (VES), Subsurface Investigation, Comparative Performance

Abstract

Comparative study on performance of an imported (Ohmega) resistivity meter (RMA) and a locally fabricated (PZ-02) resistivity meter (RMB) was carried out with a view to evaluate the data measurement accuracy and reliability. Four 2-D resistivity profiling and twelve vertical electrical soundings (VES) were acquired from two study sites within Elizade University campus. The dipole-dipole and VES datasets obtained were statistically analyzed. 2-D Subsurface modeling was carried out using Dipro inversion software; while VES data interpretation was done through manual partial curve matching and WinResist iteration for geoelectric models refinement. At Site 1, the dipole-dipole analysis statistically revealed divergent performance rating for both resistivity meters. The poor statistical agreement at Site 1 was attributed to extreme outlier readings at specific electrode positions. The 2-D resistivity structure obtained at Site 1 revealed that both resistivity images did not delineate similar subsurface structure, with significant variation in RMS error; RMA (0.0961) and RMB (0.3489). At Site 2, the dipole-dipole data analysis for both resistivity meters showed very close agreement, as confirmed by the statistical analysis results. The 2-D inversion RMS errors of 0.0615 (RMA) and 0.0990 (RMB) support that the performance of both resistivity meters closely agree at Site 2. Obtained H, HA, KH VES type curves distributed across six depth sounding curves; shows 50% agreement. The comparative assessment shows that the performance of locally fabricated resistivity meter (RMB) is within acceptable limit, when compared to that of the imported resistivity meter (RMA) in near subsurface geophysical investigation.

Dimensions

Adegoke, A. O., Adiat, K. A. N., and Omosuyi, G. O. (2020). Fabrication of resistivity meter and its evaluation within shallow depth of investigation. Global Journal of Engineering and Technology Advances, 4(1), 15-29.

Agung Pratama, Y., and Suharsono, D. (2025). Performance Evaluation of ADS 1256 for Geoelectric Data Acquisition System: Laboratory Scale Comparative Study (Vol. 23, Number 1).

Ali, A. A., and Alkhalidy, A. A. (2026). Subsurface Soil Evaluation Using 2D Electrical Resistivity Tomography for Foundation Studies at Najaf City, Iraq. Iraqi Geological Journal, 59(1), 134–146. https://doi.org/10.46717/igj.2026.59.1C.10

de la Vega, M., Bongiovanni, M. V., and Grünhut, V. (2021). Design of a low-cost electrical resistivity meter for near surface surveys. Earth and Space Science, 8, 1-10pp. e2020EA001575. https://doi. org/10.1029/2020EA001575

Ogholaja, R. E., Akpoyibo, O., Vwavware, O. J., and Chukwusa, F. O. (2025). Application of Dipole-Dipole Electrical Resistivity for Subsurface Probing Within Golf Club Centre of University of Benin Teaching Hospital, Benin City. Nigerian Journal of Theoretical and Environmental Physics, 3(1), 1–9. https://doi.org/10.62292/njtep.v3i1.2025.65

Oladapo, M. I., Adeoye-Oladapo, O. O., and Mogaji, K. A. (2009). Hydrogeophysical study of the groundwater potential of Ilara-Mokin Southwestern Nigeria. Global Journal of Pure and Applied Sciences, 15 (2).

Rahman, M.A. (1988). Recent advances in the study of basement complex of Nigeria. In: Geological Survey of Nigeria, Precambrian Geology of Nigeria, pp. 11-43.

Reynolds, J. M. (2011). An introduction to applied and environmental geophysics, (2nd edition). Wiley-Blackwell, 796pp. An Introduction to Appliedand Environmental Geophysics

Telford, W. M., Geldart, L. P., and Sheriff, R. E. (1990). Applied geophysics, (2nd edition) Cambridge University Press, pp. 344-536.