Evaluation of The Mean Glandular Doses by Estimation and Measurement with Ionization Chamber in Mammogrpahy Examinations in Southwest Nigeria

Authors

  • Dr. Aleem Farouk A.
    Federal Medical Centre Abeokuta
  • Amidu Mustapha
  • Dr. (Mrs.) Olufunmilayo O. Alatise
  • Rasheed Ajadi

Keywords:

Mammography, Ionization-chamber, Craniocaudal, Mediolateral Oblique, Radiology

Abstract

Mammography is the primary imaging modality utilizes low energy characteristics radiation for detection of abnormal growth in breasts; and its effectiveness in breast cancer diagnosis has been widely reported. Most manufacturers of mammography machine do rely on the dance formular for calculating the Mean Glandular Dose (MGD) values on the Digital Information for Communication (DICOM) header of mammography machines. The aim of this study was to check the reliability of the MGD values estimated using the Dance formula using an ionization chamber. Five mammography machines from five tertiaries medical centres within Southwest Nigeria were considered for this research work. Direct measurement was carried out using the Ionization Chamber of the RadCal Accu-gold detector. The entrance surface dose was measured and thereafter converted to MGD using the recommendation of the American College of Radiology. The Ionization chamber recorded higher values for MGD per patients, ranging from 2.49±1.32 mGy to 6.99±3.88 mGy for CC and MLO views respectively. The MGD values per patient estimated by the detector ranged from 1.98±0.84 mGy to 5.94±2.78 mGy for CC and MLO views respectively. The MGD values measured by the Accu-Gold Ionization chamber were relatively higher when compare to the estimated MGD values from the DICOM header of the mammography machines. This may be due to the fact that some exposure factors like the compression contributed to the low dose recorded by the mammogram machine in the DICOM header. The study established the reliability of the MGD values estimated using the Dance formula

Author Biographies

Dr. Aleem Farouk A.

Department of Radiography

Senior Lecturer

Amidu Mustapha

Department of Physics

Professor

Dr. (Mrs.) Olufunmilayo O. Alatise

Department of Physics

Senior Lecturer

Rasheed Ajadi

Department of Veterinary Surgery

Professor

Dimensions

REFERENCES

1) Atta M.R, Diab H.M, El-Minyawi S.M, and Nouh S.A (2017). Assessment of the mean glandular dose for patients on the mammography machines in two major hospitals in Egypt, Al-Azhar. Al-Azhar Bulletin of Science.. Vol. 9th. Conf.; p. 155-163.

2) Berry D.A, Kathleen A. Cronin, Sylvia K. Plevritis, Dennis G. Fryback, Lauren Clarke, Marvin Zelen, Jeane S. Mandelblatt, Andrei Y. Yakovlev, J Dik F Habbema and Eric J Feuer (2005). Effects of screening and adjuvant therapy on mortality from breast cancer. N Engl J Med.; 353 (17): 1784-92. Doi: 10.1056/NEJMoa050518.

3) Bunyamin E., Artun N., and Kemal M (2023). Evaluation of the relationship between digital mammography radiation dose and patient age, breast volume and density. J. Health Sci. Med.; 615: 954 – 961.

4) Baoying Chen, Yingmei Wang, Xin Sun, Wei Guo, Ming Zhao, Guangbin Cui, Lina Hu, Pei Li, Yan Ren, Jun Feng, Jun Yu (1999). Analysis of Patient Dose in Full Field Digital Mammography. Eur J Radiol. X, 201281.; (5): 868-72.

5) Dance D.R, C.L Skinner, G. Alm Carlsson (1999). Breast Dosimetry. Applied Radiation and Isotopes, vol. 50.; pp. 185-203.

6) O. Denish M. Alen, Richard O.O, B. Felix (2024). National Diagnostic Reference Levels for digital diagnostic and screening mammography in Uganda. PLoS ONE.; 19(8).

7) Dlama Z.J and Uzochukwu (2018). Radiation Doses for Mammography and its Relationship with Anthropo-Technical Parameters. Int J Radiol Radiat Ther.; 5(1).

8) Dlama Z.J, Chukwuemeka C.N, Joshua J., Mathew G.A (2020). Assessment of mean glandular dose (MGD) in two university teaching hospitals in Northern Nigeria towards a recommendation of Dose Reference Levels (DRL) for mammography examinations. African Journal of Medical and Health Sciences.; V17, Issue 1.

9) Felicia A.A and Ojikutu R.K. Prevalence and Trends in Breast Cancer in Lagos (2009). An Int. Multi-Disciplinary Journal, Ethiop.; 3(5):1–15.

10) Hazrati S., Hadi S., Babak A., Hasan F (2010). Assessment of Gamma Dose Rate in Indoor Environments in Selected Districts of Ardabil Province, Northwestern Iran. International Journal of Occupational Hygiene.; 2(1): 42-45.

11) Huda M.A., Osman B.T., Abeer O.A, Mahmood A.T, Ibrahim I.A, Nabil A.I and Antar E.A (2016). Assessment of mean glandular dose (MGD) towards establishing diagnostics reference level in Qatar. British Journal of Medicine and Medical Research.; 14(2): 1-9.

12) Hussain B.S, Garba I., Bello F., Nuhu K.S., Mohammed S., Mansur Y., and Lawal Y (2020). Assessment of AGD of mammography examinations at the Radiology department of two tertiary hospitals located in the northwest region of Nigeria. International Radiation Protection Association.

13) ICRP (2001). Radiation and Your patient: A guide for medical practitioners; supporting Guidance 2. Ann. ICRP.; 31 (4).

14) International Commission on Radiological Protection Recommendations (2007). ICRP Publication 103. Ann ICRP.; 37 (2-4): 1-332. doi: 10.1016/j.icrp.10.003.

15) Wanbani J.S., Korir G.K., Shiyanguya M.N., and Korir I (2011). Assessment of mean glandular dose (MGD) in referral hospital in Nairobi: towards establishing diagnostics reference level. East African Medical Journal 88.; (4): 218 – 226.

16) Kaltham A.N, Norhashimah M.N, Muhammad K.A, Iza N.C and Wadha A (2024). Estimating Local Diagnostic Reference Levels for Mammography in Dubai. MDPI: Diagnostics.; 14 (1): 8.

Radcal 10X6-6M Mammography Ionization Chamber in a Chest Block

Published

2026-10-29

How to Cite

Aleem, F., Mustapha, A., Alatise, O., & Ajadi, R. (2026). Evaluation of The Mean Glandular Doses by Estimation and Measurement with Ionization Chamber in Mammogrpahy Examinations in Southwest Nigeria. Nigerian Journal of Physics, 35(S), 478-483. https://doi.org/10.62292/njp.v35(s).2026.660

How to Cite

Aleem, F., Mustapha, A., Alatise, O., & Ajadi, R. (2026). Evaluation of The Mean Glandular Doses by Estimation and Measurement with Ionization Chamber in Mammogrpahy Examinations in Southwest Nigeria. Nigerian Journal of Physics, 35(S), 478-483. https://doi.org/10.62292/njp.v35(s).2026.660